• Become a member
  • Log In
The Institution of Electronics
  • Home
  • About us
    • Our Objectives
    • Our History
    • Governance of the Institution
  • The Electron Magazine
    • 2024
      • 2024 – Winter
      • 2024 – Spring
      • 2024 – Summer
      • 2024 – Autumn
    • 2025
      • 2025 – Winter
      • 2025 – Spring
      • 2025 – Summer
      • 2025 – Autumn
    • 2026
      • 2026 – Winter
      • 2026 – Summer
  • Members
    • Membership Grades and Fees
    • Members’ Resources
      • The Electron Newsletter
      • The Archives
  • Education and Projects
    • National Electronics Competition
    • Student Members’ Projects
    • Arkwright Engineering Scholarships
  • News
  • Contact Us
  • Menu Menu
Uncategorised

Switch mode hotwire thermostat

In recent EDN design ideas, we’ve seen thermostat designs that meld the functions of sensor and heater into a single device: FET, BJT, or even a simple length of fine gauge copper wire. A virtue inherent in thermostat designs that use a transistor as combined sensor and heater is that independent of whether it’s operated in linear or pulse mode, high efficiency is virtually guaranteed. 

This happens simply because when the power pass device and heater are combined, power dissipated isn’t wasted. Instead, by definition, it’s simply more heat. Result: near 100% efficiency is inevitable! Sadly, life isn’t so simple for a hotwire thermostat. While it too melds sensor and heater, they remain separate from the pass device. The power that it dissipates by operating in linear mode therefore contributes nothing to heating. It’s totally wasted, thus eroding efficiency. The potential for avoiding this inefficiency makes switch mode an interesting possibility.

Wow the engineering world with your unique design: Design Ideas Submission Guide

Figure 1 shows a design idea that achieves it.

 

Figure 1 A switch mode thermostat efficiently heats melded copper wire sensor/heater.

Figure 1 shares much in common with a linear sibling: “Hotwire thermostat: Using fine copper wire as integrated sensor and heater for temperature control” whose schematic is found in Figure 2.

Figure 2 Linear mode hot wire thermostat that uses the tempco and I2R heating of 40 AWG copper wire as a melded sensor/heater.

Their respective interfaces with a copper wire melded heater/sensor are essentially identical. Where they differ is the way op-amp A1a controls Q1.

In Figure 2, temperature dependent voltage differences between R1 and R5+R6 are linearly amplified by A1a and applied to Q1’s gate to linearly force hotwire heating to match the setpoint dialed in on R5. The result is good temperature control, but also up to 10 W of dissipation on Q1.

In Figure 1, by contrast, positive feedback around A1a via R7 forces the amplifier to latch Q1 fully ON or OFF in response to the same error signals. This simple difference improves heating efficiency enough that, unlike Figure 2, Figure 1’s Q1 needs no heatsink and the overall circuit runs from only half the supply voltage. 

Heating efficiency depends on hotwire length, and ranges from 83% for 5 feet, to 94% for 15. These numbers compare well to the linear version, that maxes out at about 50%.

Meanwhile, the calibration sequence remains the same for both switcher and linear:

Before first power up, allow sensor/heater to fully equilibrate to room temperature.
Set R4 and R5 fully counter-clockwise (CCW).
Push and hold the CAL NC pushbutton.
Turn power on.
Slowly turn R4 clockwise until LED first flickers on.
Release CAL.

Thanks for the suggestion, Konstantin Kim!

Stephen Woodward’s relationship with EDN’s DI column goes back quite a long way. Over 100 submissions have been accepted since his first contribution back in 1974.

 Related Content

Using a MOSFET as a thermostatic heater
Hotwire thermostat: Using fine copper wire as integrated sensor and heater for temperature control
Self-heated ∆Vbe transistor thermostat needs no calibration
Take-back-half thermostat uses ∆Vbe transistor sensor
Square-root function improves thermostat
Fixing a fundamental flaw of self-sensing transistor thermostats
∆Vbe differential thermometer needs no calibration

<!–
googletag.cmd.push(function() { googletag.display(‘div-gpt-ad-native’); });
–>

The post Switch mode hotwire thermostat appeared first on EDN.

16 September 2024
http://institutionofelectronics.ac.uk/wp-content/uploads/2022/12/IOE_LOGO.png 0 0 http://institutionofelectronics.ac.uk/wp-content/uploads/2022/12/IOE_LOGO.png 2024-09-16 14:44:012024-09-16 14:44:01Switch mode hotwire thermostat

Latest news

  • Significantly simpler synchronous square wave circuit for frequency division by even numbers18 November 2026 - 13:16
  • Audio AI in wearables: Enabling smarter, more responsive devices18 November 2026 - 10:10
  • In-space MOSFET failure mitigation17 November 2026 - 13:57
  • Capacitor ESR challenges high-current, fast-transient power sources17 November 2026 - 10:55
  • Building AI SoCs with a continuous hardware verification strategy17 November 2026 - 06:53
  • Inspecting a DOCSIS 3.1 cable modem’s internals: Part 116 November 2026 - 13:40
  • The shocking science (and art) of plastic welding16 November 2026 - 06:33
  • Physical AI: Where AI meets the physical world13 November 2026 - 14:36
  • The tchotchke13 November 2026 - 13:33
  • Google’s Fitbit Air: Another display-less option for tech you wear12 November 2026 - 13:11
IOE LOGO 2

Become a member

click here

Become a member

click here

Become a subscriber

click here

Become a sponsor

click here

© Copyright - The Institution of Electronics | Website by WHD Solutions
  • Link to LinkedIn
  • Link to Facebook
  • Link to X
Link to: How microchannel liquid cooling trims electronic designs Link to: How microchannel liquid cooling trims electronic designs How microchannel liquid cooling trims electronic designs Link to: Experimenting with a modern solar cell Link to: Experimenting with a modern solar cell Experimenting with a modern solar cell
Scroll to top Scroll to top Scroll to top