Power Tips #159: Quieting audible noise in AC/DC and DC/DC power supplies

Careful component selection and conscious magnetic construction can avoid many common burst-mode noise sources.

Energy-efficiency standards around the world, such as Energy Star, Department of Energy Level VI and European Union Ecodesign for Energy-Related Products framework Lot 6, have driven not only higher average efficiency in AC/DC power supplies but also reduced power consumption at no load. What is now a common strategy to satisfy these standby power requirements is to enter a special low-power mode of operation that periodically enables switching for a limited amount of time and then disables switching for an extended period, known as burst mode or skip mode.

While this method is effective in reducing power consumption at light loads, it’s important to be aware of several characteristics:

  • Operating in burst mode results in a larger low-frequency ripple at the output of the power supply.
  • Only careful control-loop design will avoid load-transient performance degradation.
  • The power supply may exhibit noticeable audible noise.

If you have ever held your ear close to an adapter when it is plugged into a wall and noticed a grinding or whining noise, you are familiar with this last point already.

Magnetics construction

The core and bobbin choice for an inductor or transformer can have a strong influence on its audible noise performance when excited with a burst frequency in the 20 Hz to 20 kHz range. To illustrate this, consider the effect of Lorentz force on the transformer shown in Figure 1 using an economic transformer design (ETD) core.


Figure 1 This image shows Lorentz force on a transformer with windings perpendicular to the PCB surface. Source: Texas Instruments

This style of bobbin orients the windings to be perpendicular to the printed circuit board (PCB) surface. Using the right-hand rule, you can see in the figure that the resulting Lorentz force on the transformer windings is perpendicular to the PCB surface, meaning that this transformer will vibrate up and down against the PCB like a drum.

Using a core and bobbin that orients the windings to be parallel to the PCB avoids this effect. Figure 2 shows a planar transformer used in a half-bridge inductor-inductor-capacitor (LLC) converter. The resulting Lorentz force is parallel to the PCB surface, so this transformer will vibrate side to side.


Figure 2 This image shows Lorentz force on a transformer with windings parallel to the PCB surface. Source: Texas Instruments

Using as much of the winding window as possible by maximizing the number of turns in both primary and secondary reduces audible noise. Table 1 compares audible noise using an EE-style core shape for different combinations of primary inductance, resonant frequency and burst frequency. Using a larger number of physical turns results in a lower audible noise result, even with a similar burst frequency and peak resonant current as other configurations.

Cr (nF) Primary winding Secondary winding Lm + Lr (µH) Lr (µH) FSW in burst mode (kHz) Burst frequency (Hz) Peak resonant current (A) Peak audible noise (dB)
33 33T 2T 437 64.7 52.8 70-98 1.45 25.6
33 37T 2T 558 78.8 45.8 85-116 1.45 25.02
33 46T 3T 424 98 55.6 60-85 1.38 22.9
33 50T 3T 448 113 53.15 68-91 1.45 22.1

Table 1 This table shows a comparison of audible noise performance for different transformer parameters. Source: Texas Instruments

Varnish and glue can prevent windings within a magnetic component from vibrating against the core and generating audible noise. Figure 3 shows a comparison of measured audible noise at a light load for a 45 W flyback converter, using an unglued vs. glued inductor in a pi filter.


Figure 3 This image shows audible noise measurements for an unglued and glued inductor vs. frequency. Source: Texas Instruments

Piezoelectric effect in MLCCs

Multilayer ceramic capacitors (MLCCs) offer lower equivalent series resistance and have a lower profile than electrolytic or film equivalents; thus, MLCCs can be a compelling choice for decoupling, snubbing or resonant capacitance in AC/DC power supplies. As illustrated in Figure 4, MLCCs are prone to the piezoelectric effect, where pulsating currents cause the ceramic material to expand and contract. In extreme cases, this flexes the PCB in the area where the capacitor is mounted and generates audible noise.


Figure 4 This image illustrates the piezoelectric effect on a ceramic capacitor. Source: Texas Instruments

Class II ceramics such as X7R or X5R are most prone to the piezoelectric effect given the ferroelectric properties of the dielectric. Class I ceramics such as NP0 and C0G use a paraelectric dielectric and therefore are not prone to piezoelectric effects that cause audible noise. Layout techniques such as orienting ceramic capacitors to be parallel with the shortest edge of the PCB minimize the possibility of the PCB flexing. If surface-mount components on both sides of the PCB are acceptable, then placing ceramics symmetrically along the top and bottom surface of the PCB (Figure 5) creates a vibration cancellation effect.


Figure 5 This image illustrates using symmetrical part placement for a vibration cancellation effect. Source: Texas Instruments

Specialized burst modes

The last approach is to use controllers with specialized burst-mode switching patterns that are designed to minimize audible noise. An example would be the UCC256404 from Texas Instruments (TI), where the current in the power stage ramps up slowly to minimize the amount of vibration in the audible range. Figure 6 illustrates the resonant current (ch4) slowly ramping up and ramping down during a switching packet.


Figure 6 This image shows the slow ramp-up and ramp-down of the resonant current in an LLC converter operating in burst mode. Source: Texas Instruments

Another approach is to attempt to directly manage the burst frequency to skip the majority of the frequency range where humans are most susceptible to audible noise. The TI UCC25661 employs this scheme, keeping the burst frequency below 400 Hz or above 25 kHz.

Conclusion

AC/DC power supplies that exhibit noticeable audible noise at light loads can be a nuisance for designers. Careful selection of power-stage components and conscious design of magnetic construction can avoid many common sources of audible noise when operating in burst mode.

Ben Lough is a systems engineer in Texas Instruments’ Power Design Services team, focused on power factor correction and isolated DC/DC conversion. He received master’s and bachelor’s degrees in electrical and computer engineering from Ohio State University.

 

Related Content

  • Power Tips #105: How to achieve low standby power for an isolated power supply
  • Power Tips #139: How to simplify AC/DC flyback design with a self-biased converter
  • Power Tips #95: Optimize efficiency in an active-clamp flyback design

The post Power Tips #159: Quieting audible noise in AC/DC and DC/DC power supplies appeared first on EDN.

24 November 2026
http://institutionofelectronics.ac.uk/wp-content/uploads/2022/12/IOE_LOGO.png 0 0 whdsolutions http://institutionofelectronics.ac.uk/wp-content/uploads/2022/12/IOE_LOGO.png whdsolutions2026-11-24 13:13:322026-11-24 13:13:32Power Tips #159: Quieting audible noise in AC/DC and DC/DC power supplies

Latest news

  • Power Tips #159: Quieting audible noise in AC/DC and DC/DC power supplies24 November 2026 - 13:13
  • Preparing for the EU CRA with hardware security verification24 November 2026 - 08:10
  • How embedded sensors are modernizing smart bathroom23 November 2026 - 16:55
  • Building smart environments with IoT development kits23 November 2026 - 15:52
  • A holiday shopping guide for engineers: 2026 edition23 November 2026 - 13:48
  • How do power management ICs improve efficiency in smart homes and cities?20 November 2026 - 15:52
  • When an energy-efficient design meets harsh reality20 November 2026 - 13:50
  • Ensuring robust DOCSIS 3.1 or satellite coexistence with MoCA 2.519 November 2026 - 13:32
  • Are DC data centers the solution to AI scale?19 November 2026 - 07:26
  • Compact LEDs expand multi-color lighting options19 November 2026 - 01:23
IOE LOGO 2

Become a member

click here

Become a member

click here

Become a subscriber

click here

Become a sponsor

click here

© Copyright - The Institution of Electronics | Website by WHD Solutions
  • Link to LinkedIn
  • Link to Facebook
  • Link to X
Link to: Preparing for the EU CRA with hardware security verification Link to: Preparing for the EU CRA with hardware security verification Preparing for the EU CRA with hardware security verification
Scroll to top Scroll to top Scroll to top