Positive analog feedback linearizes 4 to 20 mA PRTD transmitter

I recently published a simple design for a platinum resistance detector (PRTD) 4 to 20mA transmitter circuit, illustrated in Figure 1.

Figure 1 The PRTD 4 to 20 mA loop transmitter with constant current PRTD excitation that relies on 2nd order software nonlinearity correction math, ToC= (-u + (u2 – 4wx)1/2)/(2w).

Wow the engineering world with your unique design: Design Ideas Submission Guide

The simplicity of Figure 1’s circuitry is somewhat compromised, however, by its need for PRTD nonlinearity correction in software:

u and w constant and x = RPRTD@0oC – RPRTD@0oT
ToC= (-u + (u2 – 4wx)1/2)/(2w)

Unfortunately, implementing such quadratic floating-point arithmetic in a small system might be inconveniently costly in code complexity, program memory requirements, and processing time.

But fortunately, there’s a cool, clever, comparably accurate, code-ware-lite, and still (reasonably) uncomplicated alternative (analog) solution. It’s explained in this article “Design Note 45: Signal Conditioning for Platinum Temperature Transducers,” by (whom else?) famed designer Jim Williams.

Figure 2, shamelessly copied from William’s article, showcases his analog solution to PRTD nonlinearity.

Figure 2 A platinum RTD bridge where feedback to the bridge from A3 linearizes the circuit. Source: Jim Williams

Williams explains: The nonlinearity could cause several degrees of error over the circuit’s 0°C to 400°C operating range. The bridge’s output is fed to instrumentation amplifier A3, which provides differential gain while simultaneously supplying nonlinearity correction. The correction is implemented by feeding a portion of A3’s output back to A1’s input via the 10k to 250k divider. This causes the current supplied to Rp to slightly shift with its operating point, compensating sensor nonlinearity to within ±0.05°C.

Figure 3 shows William’s basic idea melded onto Figure 1’s current transmitter concept.

Figure 3 A PRTD transmitter based on the classic LM10 op-amp plus a 200 mV precision reference combo.

R5 provides PRTD-linearizing positive feedback to sensor excitation over the temperature range of -130 °C to +380 °C.

Here, linearity correction is routed through R5 to the LM10 internal voltage reference, where it is inverted to become positive feedback. The resulting “slight shift in operating point” (about 4% over the full temperature range) duplicates William’s basic idea to achieve the measurement linearity plotted in Figure 4.

Figure 4 Positive feedback reduces linearity error to < ±0.05 oC over -127 oC to +380 oC. The x-axis = Io (mA),  left y-axis = PRTD temperature, right y-axis = linearity error. T oC = 31.7(Io – 8mA).

Of course, to consistently achieve this ppm level of accuracy and linearity probably needs an iterative calibration process like the one William’s describes. Figure 5 shows the modified circuit from Figure 3, which includes three additional trims to enable post-assembly tweaking using his procedure.

Figure 5 Linearized temperature transmitter modified for a post-assembly tweaking using his procedure.

Substituting selected precision resistors for the PRTD at chosen calibration points is vital to making the round-robin process feasible. Using actual variable temperatures would take impossibly long! Unfortunately, super precise decade boxes like the one William’s describes are also super scarce commodities. So, three suitable standard value resistors, along with the corresponding simulated temperatures and 4-20 mA loop currents, are suggested in Figure 5.  They are:

51.7 Ω = -121 oC = 4.183 mA
100 Ω = 0 oC = 8.000 mA
237 Ω = 371 oC = 19.70 mA

Happy tweaking!

Oh yeah, to avoid overheating in Q1, it should ideally be in a TO-220 or similar package if Vloop > 15 V.

Related Content

  • Simple but accurate 4 to 20 mA two-wire transmitter for PRTDs
  • The power of practical positive feedback to perfect PRTDs
  • Improved PRTD circuit is product of EDN DI teamwork
  • Platinum-RTD-based circuit provides high performance with few components
  • DIY RTD for a DMM

The post Positive analog feedback linearizes 4 to 20 mA PRTD transmitter appeared first on EDN.

2 September 2025
http://institutionofelectronics.ac.uk/wp-content/uploads/2022/12/IOE_LOGO.png 0 0 whdsolutions http://institutionofelectronics.ac.uk/wp-content/uploads/2022/12/IOE_LOGO.png whdsolutions2025-09-02 18:05:102025-09-02 18:05:10Positive analog feedback linearizes 4 to 20 mA PRTD transmitter

Latest news

  • TP-Link’s Tapo P110M smart plug: Matter and energy monitoring matter12 October 2026 - 13:16
  • Measurement bandwidth9 October 2026 - 13:56
  • Practical design for a multi-output flyback converter with improved cross-regulation9 October 2026 - 08:50
  • The multi-gig Ethernet migration: Motivations and implementations8 October 2026 - 13:29
  • GaN FET meets megawatt-scale demands7 October 2026 - 20:15
  • FPGA IP accelerates deterministic networking7 October 2026 - 20:15
  • Microphone array advances acoustic detection7 October 2026 - 20:15
  • Quad beamformer simplifies X-band radar design7 October 2026 - 20:15
  • Global-shutter sensor raises pixel density7 October 2026 - 20:15
  • An unbuttoned circuit for setting digital pots7 October 2026 - 13:10
IOE LOGO 2

Become a member

click here

Become a member

click here

Become a subscriber

click here

Become a sponsor

click here

© Copyright - The Institution of Electronics | Website by WHD Solutions
  • Link to LinkedIn
  • Link to Facebook
  • Link to X
Link to: EMI fundamentals for spacecraft avionics & satellite applications Link to: EMI fundamentals for spacecraft avionics & satellite applications EMI fundamentals for spacecraft avionics & satellite applications Link to: A temperature-compensated, calibration-free anti-log amplifier Link to: A temperature-compensated, calibration-free anti-log amplifier A temperature-compensated, calibration-free anti-log amplifier
Scroll to top Scroll to top Scroll to top