• Become a member
  • Log In
The Institution of Electronics
  • Home
  • About us
    • Our Objectives
    • Our History
    • Governance of the Institution
  • The Electron Magazine
    • 2024
      • 2024 – Winter
      • 2024 – Spring
      • 2024 – Summer
      • 2024 – Autumn
    • 2025
      • 2025 – Winter
      • 2025 – Spring
      • 2025 – Summer
      • 2025 – Autumn
    • 2026
      • 2026 – Winter
  • Members
    • Membership Grades and Fees
    • Members’ Resources
      • The Electron Newsletter
      • The Archives
  • Education and Projects
    • National Electronics Competition
    • Student Members’ Projects
    • Arkwright Engineering Scholarships
  • News
  • Contact Us
  • Menu Menu
Uncategorised

BJT is accurate sensor for absolute temperature in Kelvin and Rankine

Simple math implemented in a (very) simple circuit. What’s not to like?

A very cool (also warm!) property of the base-emitter junction of (most) small signal BJTs is the ΔVbe temperature-sensing effect.  ΔVbe temperature measurement is aptly described and applied here by famed and forever remembered analog design guru Jim Williams (see page 7):

At room temperature, the Vbe junction diode shifts 59.16mV per decade of current. The temperature dependence of this constant is 0.33%/°C, or 198μV/°C. This ΔVbe versus current relationship holds, regardless of the Vbe diode’s absolute value.

Wow the engineering world with your unique design: Design Ideas Submission Guide

Rearranging Williams’ math, since 198uV=1V/5050, 198μV/°C per current decade works out to (the easier to remember…ha!) ΔVbe/°C = Log10(Current-ratio)/5050.  So, if we need any given ΔVbe/°C, the required

Current-ratio = 10^(5050 ΔVbe/°C).

For example, for ΔVbe/°C = 100uV, Current-ratio = 10^(5050 * 100uV) = 10^(0.5050) = 3.20

Of course, this trick also works for Fahrenheit, albeit with a different scale factor.  Since 1 °F = 5/9 of 1°C, for Fahrenheit the corresponding Current-ratio = 10^(9090 ΔVbe/°F).  Therefore, for the 100uV example, if ΔVbe/°F = 100uV, then Current-ratio = 10^(9090 * 100uV) = 10^(0.9090) = 8.11

Figure 1 shows this simple math implemented in a (very) simple circuit:


Figure 1
An ordinary BJT Q1 makes an accurate absolute temperature sensor in two different units (K and R).

Here’s how it works. Switch U1a applies alternating current ratio drive to sensor Q1 per Williams’ method.  The ratio is (approximately) Current-ratio = (1/R1 + 1/R2)/(1/R2) = (R2/R1 + 1) = 3.20 for measurement in units of Celsius (Kelvin) and = 8.11 for Fahrenheit (Rankine).  The “approximately” thing comes in because the resistor ratio needed to be fudged (slightly) to compensate for the few 10s of mV of varying difference between V+ and Q1’s Vbe and thus make the current ratios accurately equal to the calculated values.

The resulting 100uVpp per degree AC signal is synchronously rectified by U1b and filtered by C3 to become the 100uV per degree of absolute temperature DC output signal suitable for direct input to a DMM.  A ~5kHz clock signal for current switching and rectification is provided by U1c, with a little help from one side of U1a.

Note that, per Williams’ analysis of the ΔVbe effect, accuracy of temperature measurement relies only on the accuracy of the current ratio and therefore on only the precision of R1 and R2.  No other reference is required or relevant and any 2N3904 will do. 

The V+ supply, for example, can vary from 3 to 6 volts without affecting accuracy.  Passive output impedance is roughly 10k.  So, loading by a typical 10M DMM input won’t either.

Thanks, Jim!

Stephen Woodward‘s relationship with EDN’s DI column goes back quite a long way. Over 200 submissions have been accepted since his first contribution back in 1974.  They have included best Design Idea of the year in 1974 and 2001.

Related Content 

  • Temperature compensation with a simple resistance temperature detector
  • A temperature-compensated, calibration-free anti-log amplifier
  • Thermopile sensors: A guide to non-contact temperature measurement

The post BJT is accurate sensor for absolute temperature in Kelvin and Rankine appeared first on EDN.

22 April 2026
http://institutionofelectronics.ac.uk/wp-content/uploads/2022/12/IOE_LOGO.png 0 0 whdsolutions http://institutionofelectronics.ac.uk/wp-content/uploads/2022/12/IOE_LOGO.png whdsolutions2026-04-22 15:45:222026-04-22 15:45:22BJT is accurate sensor for absolute temperature in Kelvin and Rankine

Latest news

  • Four-channel USB-UART IC boosts server management13 August 2026 - 05:08
  • eFuse speeds overcurrent detection13 August 2026 - 05:08
  • Memory platform tackles AI bottlenecks13 August 2026 - 05:08
  • 6.5-kV SiC MOSFET reaches 8-kV blocking13 August 2026 - 05:08
  • Made by Google 2026: This limited silicon-supply situation really sucks13 August 2026 - 05:08
  • Cheap and cheerful LMC555 RC PWM pulse generator12 August 2026 - 13:56
  • Record high wafer shipments. Can fabs keep pace?12 August 2026 - 07:51
  • Analog uncertainty-aware design: How it replaces Monte Carlo with certifiable yield intelligence11 August 2026 - 16:31
  • Automotive low side output switch architecture suitable for 8 to 48 volt buses and beyond11 August 2026 - 13:26
  • Inference 2.0: How enterprise AI is reshaping AI system architectures11 August 2026 - 07:19
IOE LOGO 2

Become a member

click here

Become a member

click here

Become a subscriber

click here

Become a sponsor

click here

© Copyright - The Institution of Electronics | Website by WHD Solutions
  • Link to LinkedIn
  • Link to Facebook
  • Link to X
Link to: The system architect’s sketchbook: GenZLens built in a dorm Link to: The system architect’s sketchbook: GenZLens built in a dorm The system architect’s sketchbook: GenZLens built in a dorm Link to: How to implement OTA firmware update on MCUs Link to: How to implement OTA firmware update on MCUs How to implement OTA firmware update on MCUs
Scroll to top Scroll to top Scroll to top